{"product_id":"scopevalet-pull-thru-mini-2-6mm-x-2200mm-case-of-180","title":"ScopeValet™ Pull Thru™ Mini - 2.6mm x 2200mm | Case of 180","description":"\u003ch4 data-mce-fragment=\"1\"\u003eA Revolutionary Single Use Endoscope Lumen Cleaning Device\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eUnique Three Wiper Design removes residue in a SINGLE PASS\u003c\/h4\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003eScientifically proven advancement over existing brush technology*\u003c\/h4\u003e\n\u003cp class=\"display_area\" data-mce-fragment=\"1\"\u003eThe ScopeValet™ PULL THRU™ MINI is an endoscope channel cleaning device used during manual cleaning, which is designed to effectively clean bronchoscopes and small channel GI Endoscopes with lumen channel sizes 1.4mm - 2.6mm with a single pass. The PULL THRU™ MINI is designed to significantly reduce the time required to manually clean endoscope channels and to improve the overall efficacy of the cleaning process when compared to traditional bristle brushes.*\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe unique three wiper design of the ScopeValet™ PULL THRU™ MINI provides a complete circumferential seal in the endoscope channel, thereby removing almost all residue in a single pass.\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003eThe 360° seal creates a vacuum which draws detergent through the channel removing residue from crevices or other areas of minor damage in the channel. The vacuum also ensures the channel is completely filled with detergent to attack and remove bioburden.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eFEATURES\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEffectively cleans endoscope channels from 1.4 to 2.6mm with a single pass.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUnique wiper element design provides a complete circumferential seal in the endoscope channel with a piston like action thereby removing almost all residue.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eReduces the time required to manually clean endoscope channels.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRemoves the residue bristle brushes leave behind, enabling detergents to attack and remove bioburden more effectively.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePULL THRU™ MINI action is consistent every time, which reduces any variation in cleaning method between users.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDisposable\/single use device, which removes the need for the complicated and expensive cleaning of traditional brushes.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eScientifically proven to significantly enhance the efficiency of the cleaning process when compared to traditional bristle brushes.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWipers are constructed of soft plastic, non-abrasive material and will not harm the endoscope channel walls.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003e*SUMMARY OF SCIENTIFIC PAPERS\u003c\/h5\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eBirmingham Study:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eassessed the performance of a PULL THRU™ after one (1) pass through a pre contaminated channel against a bristle brush after five (5) passes through the channel. A Ninhydrin test was used to measure detectable protein and a visual inspection was made to detect soil. The results indicate that a single pass of the PULL THRU™ is as effective as 5 passes of the bristle brush tested against.\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConclusion: A single pass of the PULL THRU™ is as effective as 5 passes of the bristle brush tested against.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eDeventer Study:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ecompares the amount of protein removal in the channel of a range of colonoscopes after brushing with reusable bristle brush, a single use bristle brush and a PULL THRU™. The device was passed down the channel of the colonoscope once when the scope was manually cleaned. The protein loading in the channels was measured prior and subsequent to cleaning.\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConclusions: The PULL THRU™ removes 18% more atp (organic material) than brushing with a single use brush. The PULL THRU™ removes 30% more material than reusable brushes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eCharlton Study:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAustralian Infect Control 2007; 12(3): 81-90 The Charlton study measures the weight of pre loaded soil removed after a single pass of PULL THRU™ versus six passes of the bristle brushes the comparison was made against.\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConclusion: The PULL THRU™ significantly increases cleaning efficiency, removing between 96% to 100% of residual soil on a single pass, compared to traditional brushes, which remove between 29% and 90% after three brushing cycles.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 data-mce-fragment=\"1\"\u003eDIRECTIONS FOR USE\u003c\/h5\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWorking Channel: 1.4-2.6 mm ID\u003cbr data-mce-fragment=\"1\"\u003eWorking Length: approximately 220cm\u003cbr data-mce-fragment=\"1\"\u003eCompatible with OLYMPUS® \/ FUJINON® \/ PENTAX® Bronchoscopes and GI Endoscopes with channels in the designated range (1.4-2.6 mm ID)\u003c\/p\u003e\n\u003col data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eBe sure to use the PULL THRU™ MINI on wet channels.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eOpen the pouch and remove the PULL THRU™ MINI channel cleaning device from the package.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCheck the working channel inner diameter by inserting the PULL THRU™ MINI head 2 into the distal end of the scope; if too tight or too loose check channel inner diameter against scope manufacturer’s instructions. The wipers should pass easily through the channel.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eBRONCHOSCOPE SUCTION PORT:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsert the short tip end of the PULL THRU™ MINI channel cleaning device into the suction port. Advance the Mini PULL THRU™ channel cleaning device using short 2 cm strokes until it exits the distal end. Once through the distal end, grasp this end and pull the device slowly to prevent spraying matter when the Mini PULL THRU™ channel cleaning device head exits the channel.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eBRONCHOSCOPE BIOPSY PORT:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsert the short tip 1 end of the PULL THRU™ MINI channel cleaning device into the biopsy port. Advance the Mini PULL THRU™ channel cleaning device using short 2 cm strokes until it exits the distal end. Once through the distal end, grasp this end and pull the device slowly to prevent spraying matter when the Mini PULL THRU™ channel cleaning device head exits the channel.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eGI ENDOSCOPE CHANNEL 1:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsert device into the suction cylinder through to the suction connector. If there is resistance, insert device through the suction connector to the suction cylinder. Once the plastic sheath 1 has exited the distal end of the suction channel, pull the device through the endoscope until it has passed completely through the suction channel.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eGI ENDOSCOPE CHANNEL 2:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsert device into the suction cylinder through to the distal tip of endoscope. Once the plastic sheath 1 has exited the distal tip, pull the device through the endoscope until it has passed completely through this channel.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eGI ENDOSCOPE CHANNEL 3:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eInsert the device into the biopsy channel port through to the distal tip of endoscope. Once the plastic sheath 1 has exited the distal tip of the biopsy channel, pull the device through the biopsy channel until it has passed completely through this channel.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eDispose of the device after use.\u003c\/p\u003e","brand":"Ruhof","offers":[{"title":"Case of 180","offer_id":40226495332422,"sku":"RU-MPT180R","price":392.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0550\/5659\/7062\/products\/MPT_ScopeValet_PULL_THRU_MINI_1024x1024_5158b337-b98e-4daf-a28c-629035a79721.jpg?v=1659114841","url":"https:\/\/medute.com\/products\/scopevalet-pull-thru-mini-2-6mm-x-2200mm-case-of-180","provider":"Medute","version":"1.0","type":"link"}