Liveo™ Pharma-50 Tubing - 50A Durometer; 0.040 inch ID x 0.085 inch OD (1.02 mm x 2.16 mm) x 50 ft coil (15.24 m) - T3534

Manufactured by DuPont™ Liveo™ Healthcare Solutions, this Liveo™ Pharma-50 silicone tubing is designed for the transfer of high-purity fluids in pharmaceutical and biotechnological manufacturing processes. As per the manufacturer this product is not to be used in medical applications involving implantation in the human body or contact with internal body fluids and tissues.
Technical Detail 50A Durometer; 0.040 inch ID x 0.085 inch OD (1.02 mm x 2.16 mm) x 50 ft coil (15.24 m)
Materials Silicone
CAD Model Available No
Packaging 50 ft (15.24 m) coil
Manufacturing Environment Classification ISO Class 7 / 10,000 / Grade C
Manufacturing Aids - Mold Release - Lubricant used No
Colorant in Part No
Regrind Used to Manufacture This Part No
Hazardous Goods No
Product Shelf Life Non-Irradiation (months) 60
Animal Derived Ingredients (BSE/TSE) Conforms with EMA/410/01 rev. 3
California Prop. 65 NO Substances on the California Proposition 65 list have been knowingly or intentionally added
California Prop. 65 List Date 5/31/2022 08:00:00 pm
Conflict Minerals Not known to contain tantalum, tin, tungsten or gold.
EU MDR 10.4.1 (CMR/ED) No Substance(s) Present Above Threshold
European Pharmacopoeia (EP) 3.1.X Information Not Available
Human Derived Ingredients Does NOT intentionally contain human derived ingredients
Latex Does NOT intentionally contain natural latex
Latex in Packaging Information Not Available
Medicinal Substances Does NOT intentionally contain medicinal substances
Nanomaterials Does NOT intentionally contain nanomaterials
PFAS Does NOT intentionally contain PFAS
Pyrogens Pyrogen free - Tested via USP <151>/<161>
REACH SVHC No Substance(s) Present Above Threshold
REACH SVHC Candidate List 2026 February 04 (253 Substances)
RoHS3 (2015/863) Conforms to requirements of RoHS 2015/863 (RoHS3)
EtO Compatible Yes
Gamma Compatible Yes
X-Ray Compatible Yes
Biocompatibility tested ISO 10993 Yes
ISO 10993-X Claim Based on Finished Component
USP Biocompatibility 87 Finished component passes USP<87>
USP Biocompatibility 88 passes USP <88>, temperature not stated
USP Biocompatibility Claim Based On Finished Component
Residual Solvents: Tested via ICH Q3C Standard No ICH Q3C Testing Performed
Elemental Impurities: Tested via ICH Q3D Standard No ICH Q3D Testing Performed
Protein Absorption Data Available No
Extractables Testing Claims No Extractables Testing Performed
Visible-Subvisible Particulate Claim USP <788>
Bioburden USP 61 62 No bioburden information available
Tested via USP 661.1 Yes
Integrity Tested? No


$100.95

QS-T3534

QSN

Platinum-Cured Silicone

200 In Stock


  • Mastercard
  • Visa
  • American Express
  • Downloadable Logos for Use Online – JCB USA
  • Discover logo and symbol, meaning ...
  • Diners Club International Logo Credit ...
Super fast delivery 1-2 Processing time, 3-4 business days delivery time
30 days return policy Fast refunds
Secure payment Safe and secure payment
Always the best price Competitive prices


Manufactured by DuPont™ Liveo™ Healthcare Solutions, this Liveo™ Pharma-50 silicone tubing is designed for the transfer of high-purity fluids in pharmaceutical and biotechnological manufacturing processes. As per the manufacturer this product is not to be used in medical applications involving implantation in the human body or contact with internal body fluids and tissues.
Technical Detail 50A Durometer; 0.040 inch ID x 0.085 inch OD (1.02 mm x 2.16 mm) x 50 ft coil (15.24 m)
Materials Silicone
CAD Model Available No
Packaging 50 ft (15.24 m) coil
Manufacturing Environment Classification ISO Class 7 / 10,000 / Grade C
Manufacturing Aids - Mold Release - Lubricant used No
Colorant in Part No
Regrind Used to Manufacture This Part No
Hazardous Goods No
Product Shelf Life Non-Irradiation (months) 60
Animal Derived Ingredients (BSE/TSE) Conforms with EMA/410/01 rev. 3
California Prop. 65 NO Substances on the California Proposition 65 list have been knowingly or intentionally added
California Prop. 65 List Date 5/31/2022 08:00:00 pm
Conflict Minerals Not known to contain tantalum, tin, tungsten or gold.
EU MDR 10.4.1 (CMR/ED) No Substance(s) Present Above Threshold
European Pharmacopoeia (EP) 3.1.X Information Not Available
Human Derived Ingredients Does NOT intentionally contain human derived ingredients
Latex Does NOT intentionally contain natural latex
Latex in Packaging Information Not Available
Medicinal Substances Does NOT intentionally contain medicinal substances
Nanomaterials Does NOT intentionally contain nanomaterials
PFAS Does NOT intentionally contain PFAS
Pyrogens Pyrogen free - Tested via USP <151>/<161>
REACH SVHC No Substance(s) Present Above Threshold
REACH SVHC Candidate List 2026 February 04 (253 Substances)
RoHS3 (2015/863) Conforms to requirements of RoHS 2015/863 (RoHS3)
EtO Compatible Yes
Gamma Compatible Yes
X-Ray Compatible Yes
Biocompatibility tested ISO 10993 Yes
ISO 10993-X Claim Based on Finished Component
USP Biocompatibility 87 Finished component passes USP<87>
USP Biocompatibility 88 passes USP <88>, temperature not stated
USP Biocompatibility Claim Based On Finished Component
Residual Solvents: Tested via ICH Q3C Standard No ICH Q3C Testing Performed
Elemental Impurities: Tested via ICH Q3D Standard No ICH Q3D Testing Performed
Protein Absorption Data Available No
Extractables Testing Claims No Extractables Testing Performed
Visible-Subvisible Particulate Claim USP <788>
Bioburden USP 61 62 No bioburden information available
Tested via USP 661.1 Yes
Integrity Tested? No