Best Deals
Special Products
3-Way Stopcock, 2 Female Luer Locks, Male Luer Slip, Vented Female and Non-Vented Male Caps - 0.106 inch Hi-Flow Thru Hole (2.7 mm); 29 psi - 17624
Qosina offers a variety of stopcocks that are in stock and ready for immediate delivery. Equipped with caps, Qosina part # 17624 is a 3-way stopcock that features 2 female luer locks and a male luer slip. With a tinted polysulfone body, a blue HDPE handle and polypropylene caps, this 3-way stopcock can withstand up to 29 psi and is designed for the manual regulation of liquid or gas flow in a line. Qosina carries a large selection of stopcocks and manifolds for all your component needs.
| Technical Detail | 0.106 inch Hi-Flow Thru Hole (2.7 mm); 29 psi |
| Materials | PSU Colorant PP HDPE Colorant Silicone Silicone |
| CAD Model Available | No |
| Manufacturing Environment Classification | ISO Class 8 / 100,000 / Grade D |
| Manufacturing Aids - Mold Release - Lubricant used | No |
| Colorant in Part | Yes |
| Regrind Used to Manufacture This Part | No |
| Hazardous Goods | No |
| Product Shelf Life Non-Irradiation (months) | 60 |
| Product Shelf Life Post-Irradiation (months) | 36 |
| Animal Derived Ingredients (BSE/TSE) | Animal Derived Component Free (ADCF) |
| California Prop. 65 | NO Substances on the California Proposition 65 list have been knowingly or intentionally added |
| Conflict Minerals | Not known to contain tantalum, tin, tungsten or gold. |
| European Pharmacopoeia (EP) 3.1.X | Information Not Available |
| Latex | Does NOT intentionally contain natural latex |
| Latex in Packaging | Does NOT intentionally contain natural latex |
| Pyrogens | Not Tested for Pyrogens |
| RoHS3 (2015/863) | Does not conform to requirements of RoHS 2015/863 (RoHS3) |
| EtO Compatible | Yes |
| Gamma Compatible | Yes |
| Residual Solvents: Tested via ICH Q3C Standard | No ICH Q3C Testing Performed |
| Elemental Impurities: Tested via ICH Q3D Standard | No ICH Q3D Testing Performed |
| Protein Absorption Data Available | No |
| Extractables Testing Claims | No Extractables Testing Performed |
| Visible-Subvisible Particulate Claim | Information Not Available |
| Bioburden USP 61 62 | No bioburden information available |
| Tested via USP 661.1 | No |
| Integrity Tested? | No |
$4.95
QS-17624
QSN
Stopcocks
200 In Stock
Qosina offers a variety of stopcocks that are in stock and ready for immediate delivery. Equipped with caps, Qosina part # 17624 is a 3-way stopcock that features 2 female luer locks and a male luer slip. With a tinted polysulfone body, a blue HDPE handle and polypropylene caps, this 3-way stopcock can withstand up to 29 psi and is designed for the manual regulation of liquid or gas flow in a line. Qosina carries a large selection of stopcocks and manifolds for all your component needs.
| Technical Detail | 0.106 inch Hi-Flow Thru Hole (2.7 mm); 29 psi |
| Materials | PSU Colorant PP HDPE Colorant Silicone Silicone |
| CAD Model Available | No |
| Manufacturing Environment Classification | ISO Class 8 / 100,000 / Grade D |
| Manufacturing Aids - Mold Release - Lubricant used | No |
| Colorant in Part | Yes |
| Regrind Used to Manufacture This Part | No |
| Hazardous Goods | No |
| Product Shelf Life Non-Irradiation (months) | 60 |
| Product Shelf Life Post-Irradiation (months) | 36 |
| Animal Derived Ingredients (BSE/TSE) | Animal Derived Component Free (ADCF) |
| California Prop. 65 | NO Substances on the California Proposition 65 list have been knowingly or intentionally added |
| Conflict Minerals | Not known to contain tantalum, tin, tungsten or gold. |
| European Pharmacopoeia (EP) 3.1.X | Information Not Available |
| Latex | Does NOT intentionally contain natural latex |
| Latex in Packaging | Does NOT intentionally contain natural latex |
| Pyrogens | Not Tested for Pyrogens |
| RoHS3 (2015/863) | Does not conform to requirements of RoHS 2015/863 (RoHS3) |
| EtO Compatible | Yes |
| Gamma Compatible | Yes |
| Residual Solvents: Tested via ICH Q3C Standard | No ICH Q3C Testing Performed |
| Elemental Impurities: Tested via ICH Q3D Standard | No ICH Q3D Testing Performed |
| Protein Absorption Data Available | No |
| Extractables Testing Claims | No Extractables Testing Performed |
| Visible-Subvisible Particulate Claim | Information Not Available |
| Bioburden USP 61 62 | No bioburden information available |
| Tested via USP 661.1 | No |
| Integrity Tested? | No |