Best Deals
Special Products
iDOT™ Single-Use O2 Sensor Bag Port - Fits Polestar Technologies Fiber Optic Cable - 49012
Part number 49012 is an integrated Disposable Optical Transducer (iDOT™) gamma-stable bag port. This component allows for non-invasive in situ monitoring of O2 (0-100%) and is pre-calibrated for plug-and-play use. This product features a POE bag port with PVB/LDPE sensing film, with materials that meet USP <88> requirements. Designed to work with Polestar Technologies DSP Series Optical Process Monitoring products, the bag port would attach to a Polestar fiber optic cable.
| Technical Detail | Fits Polestar Technologies Fiber Optic Cable |
| Materials | Polyolefin PVB LDPE |
| CAD Model Available | No |
| Manufacturing Environment Classification | Controlled but not formally classified |
| Manufacturing Aids - Mold Release - Lubricant used | No |
| Colorant in Part | No |
| Regrind Used to Manufacture This Part | No |
| Hazardous Goods | No |
| Product Shelf Life Non-Irradiation (months) | 24 |
| California Prop. 65 | NO Substances on the California Proposition 65 list have been knowingly or intentionally added |
| California Prop. 65 List Date | 1/26/2023 07:00:00 pm |
| Conflict Minerals | Not known to contain tantalum, tin, tungsten or gold. |
| Human Derived Ingredients | Does NOT intentionally contain human derived ingredients |
| Latex | Does NOT intentionally contain natural latex |
| Latex in Packaging | Does NOT intentionally contain natural latex |
| Medicinal Substances | Does NOT intentionally contain medicinal substances |
| Nanomaterials | Does NOT intentionally contain nanomaterials |
| Pyrogens | Not Tested for Pyrogens |
| REACH SVHC | No Substance(s) Present Above Threshold |
| RoHS3 (2015/863) | Conforms to requirements of RoHS 2015/863 (RoHS3) |
| EtO Compatible | Yes |
| Gamma Compatible | Yes |
| USP Biocompatibility 87 | Finished component passes USP<87> |
| Residual Solvents: Tested via ICH Q3C Standard | No ICH Q3C Testing Performed |
| Elemental Impurities: Tested via ICH Q3D Standard | No ICH Q3D Testing Performed |
| Protein Absorption Data Available | No |
| Extractables Testing Claims | Other Report |
| Bioburden USP 61 62 | No bioburden information available |
| Tested via USP 661.1 | No |
| Integrity Tested? | Yes, routine random samples are tested |
$122.95
QS-49012
QSN
Single-Use Sensors
200 In Stock
Part number 49012 is an integrated Disposable Optical Transducer (iDOT™) gamma-stable bag port. This component allows for non-invasive in situ monitoring of O2 (0-100%) and is pre-calibrated for plug-and-play use. This product features a POE bag port with PVB/LDPE sensing film, with materials that meet USP <88> requirements. Designed to work with Polestar Technologies DSP Series Optical Process Monitoring products, the bag port would attach to a Polestar fiber optic cable.
| Technical Detail | Fits Polestar Technologies Fiber Optic Cable |
| Materials | Polyolefin PVB LDPE |
| CAD Model Available | No |
| Manufacturing Environment Classification | Controlled but not formally classified |
| Manufacturing Aids - Mold Release - Lubricant used | No |
| Colorant in Part | No |
| Regrind Used to Manufacture This Part | No |
| Hazardous Goods | No |
| Product Shelf Life Non-Irradiation (months) | 24 |
| California Prop. 65 | NO Substances on the California Proposition 65 list have been knowingly or intentionally added |
| California Prop. 65 List Date | 1/26/2023 07:00:00 pm |
| Conflict Minerals | Not known to contain tantalum, tin, tungsten or gold. |
| Human Derived Ingredients | Does NOT intentionally contain human derived ingredients |
| Latex | Does NOT intentionally contain natural latex |
| Latex in Packaging | Does NOT intentionally contain natural latex |
| Medicinal Substances | Does NOT intentionally contain medicinal substances |
| Nanomaterials | Does NOT intentionally contain nanomaterials |
| Pyrogens | Not Tested for Pyrogens |
| REACH SVHC | No Substance(s) Present Above Threshold |
| RoHS3 (2015/863) | Conforms to requirements of RoHS 2015/863 (RoHS3) |
| EtO Compatible | Yes |
| Gamma Compatible | Yes |
| USP Biocompatibility 87 | Finished component passes USP<87> |
| Residual Solvents: Tested via ICH Q3C Standard | No ICH Q3C Testing Performed |
| Elemental Impurities: Tested via ICH Q3D Standard | No ICH Q3D Testing Performed |
| Protein Absorption Data Available | No |
| Extractables Testing Claims | Other Report |
| Bioburden USP 61 62 | No bioburden information available |
| Tested via USP 661.1 | No |
| Integrity Tested? | Yes, routine random samples are tested |