World’s first digital stick hypothermia thermometer.
The Adtemp™ 419 features:
- The first digital extended-range thermometer
- Extended range 78.8°F to 111.0°F ±.1°F or 26.0°C to 43.9°C ±.2°C
- Replaceable 1.55V (LR41) type battery provides up to 5,000 measurements
- Integral scabbard-type carry case
- Boxed unit complete with five probe sheaths
- 12 per carton, 144 per case
- Meets the accuracy requirements for intermittent thermometers under ASTM E1112
This product not available for sale in Canada.
| Type: | Hypothermic |
| Technology: | Peak-hold |
| Scale: | Dual (°F/°C) |
| Range °F: | 78.8 to 111.0 |
| Range °C: | 26.0 to 43.9 |
| Accuracy °F: | 0.1 |
| Accuracy °C: | 0.2 |
| Response Time Oral: | 10–20 sec |
| Response Time Rectal: | 10–15 sec |
| Response Time Axillary: | 15–25 sec |
| Beeper: | Yes |
| Auto-off: | Yes |
| Memory: | Last-reading |
| Flex Probe: | No |
| Needs Sheaths: | Yes |
| Warranty: | 2 Year |
| Battery Type: | 1.55V (LR41) |
| Battery Life: | Approx. 5,000 uses |
| Latex Content: | Not made with natural rubber latex |
| Packaging: | Bulk |
| Dimensions: | 5.12" x 0.59" x 0.31" (130 mm x 15 mm x 8 mm) |
| Weight: | 0.37 oz (10.6 g) |
| Display: | LCD |
| Operating Environment: | 60.8~104.0°F, R.H. of 15~95% non-condensing |
| Storage Environment: | -4~120°F , R.H. of 15~95% non-condensing |
$134.95
419
ADC
Thermometer
17 In Stock
World’s first digital stick hypothermia thermometer.
The Adtemp™ 419 features:
- The first digital extended-range thermometer
- Extended range 78.8°F to 111.0°F ±.1°F or 26.0°C to 43.9°C ±.2°C
- Replaceable 1.55V (LR41) type battery provides up to 5,000 measurements
- Integral scabbard-type carry case
- Boxed unit complete with five probe sheaths
- 12 per carton, 144 per case
- Meets the accuracy requirements for intermittent thermometers under ASTM E1112
This product not available for sale in Canada.
| Type: | Hypothermic |
| Technology: | Peak-hold |
| Scale: | Dual (°F/°C) |
| Range °F: | 78.8 to 111.0 |
| Range °C: | 26.0 to 43.9 |
| Accuracy °F: | 0.1 |
| Accuracy °C: | 0.2 |
| Response Time Oral: | 10–20 sec |
| Response Time Rectal: | 10–15 sec |
| Response Time Axillary: | 15–25 sec |
| Beeper: | Yes |
| Auto-off: | Yes |
| Memory: | Last-reading |
| Flex Probe: | No |
| Needs Sheaths: | Yes |
| Warranty: | 2 Year |
| Battery Type: | 1.55V (LR41) |
| Battery Life: | Approx. 5,000 uses |
| Latex Content: | Not made with natural rubber latex |
| Packaging: | Bulk |
| Dimensions: | 5.12" x 0.59" x 0.31" (130 mm x 15 mm x 8 mm) |
| Weight: | 0.37 oz (10.6 g) |
| Display: | LCD |
| Operating Environment: | 60.8~104.0°F, R.H. of 15~95% non-condensing |
| Storage Environment: | -4~120°F , R.H. of 15~95% non-condensing |